고려대학교

QUICK MENU
  • 로그인
  • 고려대학교
  • KUPID
  • Library
  • Sitemap
  • English

교수진

윤명근 교수
 
연구실 하나과학관 B동 472호
연락처 02-3290-5651
E-mail radioyoon@korea.ac.kr
연구분야 - Development of proton dosimetry system using an array of fiber-optic cerenkov radiation sensor
- Development of real-time radiation beam monitoring system
- Development of reconstruction algorithm for the verification of treatment doses
- Development of regulation technology for quality assurance in radiotherapy system
- Treatment of cancer cell using alternating electric fields

학력

Ph.D. Physics, Pennsylvania State University 2001

MA, Physics, University of Massachusetts 1996

BA, Physics, Korea University 1992

주요경력

Department of Radiological Science, Yonsei University, Wonju Korea, Associate Professor (03/2011 ~ 02/2012)

Proton Therapy Center, National Cancer Center Goyang, Korea, Medical Physicist (03/2005 ~ 02/2011)

Dept. of Nano-Lab, Korea Basic Science Institute, Seoul, Korea, Senior Scientist (10/2002 ~ 02/2005)

Dept. of System LSI Samsung Electronics, Suwon, Korea, Principle Investigator (01/2002 ~ 10/2002)

주요논문 및 특허(최근 5년)

International Journals

 H Jeong, J Sung, S Oh, S Jeong, E Koh, S Hong, Myonggeun Yoon, “Inhibition of brain tumor cell proliferation by alternating electric fields” Applied Physics Letters Vol. 105, 203703 (11/2014)

 Jiwon Sung, Myonggeun Yoon, Tae Seong Baek, Dong Wook Kim, Dong Hyun Kim, “Estimate of the shielding effect on secondary cancer risk due to cone-beam CT in image-guided radiotherapy” Journal of Korean Physics Society. Vol 65, No.5, 757-762 (09/2014)

 Tae Seong Baek, Eun Ji Chung, Eui Kwan Koh, Jungju Seo, Myonggeun Yoon, “Evaluation of the accuracy of dose delivery for IMRT based on transit dosimetry” Health physics. Vol. 107, Issue3, 200-205 (09/2014)

 Boram Lee, Sunyoung Lee, Jiwon Sung, Myonggeun Yoon, “Radiotherapy-induced secondary cancer risk for breast cancer: 3D conformal therapy versus IMRT versus VMAT” J. Radiol. Prot. 34, 325-331 (06/2014)

 Myonggeun Yoon, Hyunho Lee, Jiwon Sung, Dongoh Shin, Sungho Park, Weon Kuu Chung, Geon-Ho Jahng, Dong Wook Kim, “Risk of a second cancer from scattered radiation in acoustic neuroma treatment” Journal of Korean Physics Society. Vol 64, No.12, 1919-27 (06/2014)

 Boram Lee, Sunyoung Lee, Injeong Yang, Myeonggeun Yoon, “Evaluation of the Stepwise Collimation Method for the Reduction of the Patient Dose in Full Spine Radiography” Journal of Korean Physics Society. Vol 64, No.12, 1380-4 (05/2014)

 Dong Wook Kim, Kwangzoo Chung, Weon Kuu Chung, Sun Hyun Bae, Dongoh Shin, Seongeon Hong, Sungho Park, Sung-Yong Park, Chae-Seon Hong, Young Kyung Lim, Dongho Shin, Se Byeong Lee, Hyun-ho Lee, Jiwon Sung, Myonggeun Yoon, “Risk of secondary cancers from scattered radiation during intensity-modulated radiotherapies for hepatocellular carcinoma” Radiation Oncology 9:109 (05/2014)

 Dong Wook Kim, Weon Kuu Chung, Jungwook Shin, Young Kyung Lim, Dongho Shin, Se Byeong Lee, Myongguen Yoon, Sung-Yong Park, Dong Oh Shin and Jung Keun Cho, “Secondary neutron dose measurement for proton eye treatment using an eye snout with a borated neutron absorber” Radiation Oncology. Vol. 8, 182 (07/2013)

 Eui Kwan Koh, Jungju Seo, Tae Seong Baek, Eun Ji Chung, Myonggeun Yoon, Hyun-ho Lee, “Estimate of the risk of radiation-induced cancers after linear-accelerator-based breast-cancer radiotherapy” Journal of Korean Physics Society. Vol 63, No.1, 97-103 (07/2013)

 D Kim, W Chung and Myonggeun Yoon, “Imaging doses and secondary cancer risk from kilovoltage cone-beam CT in radiation therapy”, Health Physics, 104, 499-503 (05/2013)

 D Kim, W Chung, S Ahn, Myonggeun Yoon, “Estimate of the Secondary Cancer Risk from Megavoltage CT in Tomotherapy” Journal of Korean Physics Society. Vol 62, No.8, 1199-1203 (04/2013)

 D Kim, W Chung, D Shin, S Hong, S Park, S Park, K Chung, Y Lim, D Shin, S Lee, H Lee and Myonggeun Yoon, “Risk of second cancer from scattered radiation of intensity-modulated radiotherapies with lung cancer” , Radiation Oncology. Vol. 8, 47 (03/2013)

 K Chung, Myonggeun Yoon, J Son, S Park, K Lee, D Shin, Y Lim, S Lee, “Radiochromic film based transit dosimetry for verification of dose delivery with intensity modulated radiotherapy”, Medical Physics. 40, 021725 (02/2013)

 Jinsung Kim, Myonggeun Yoon, Seonkyu Kim, Dongho Shin, Se Byeong Lee, Young Kyung Lim, Dong Wook Kim and Sung Yong Park, “three-dimensional radiochromic film dosimetry of proton clinical beams using a Gafchromic EBT2 film array”, Radiation Protection Dosimetry. Vol. 151, 272-277 (08/2012)

 Dongho Shin, Seung Hoon Yoo, Sung Ho Moon, Myonggeun Yoon, Se Byeong Lee, Sung Yong Park, “Eye tracking and gating system for proton therapy of orbital tumors” Medical Physics. Vol 39, 4265-9 (07/2012)

 Dong Wook Kim, Weon Kuu Chung, Dong Oh Shin, MyonggeunYoon, Ui-JungHwang, Jeong-Eun Rah, Hojin Jeong, Sang Yeob Lee, Dongho Shin, Se Byeong Lee and Sung Yong Park, “Dose Response of Commercially Available Optically Stimulated Luminescent Detector, Al2O3:C for Megavoltage Photons and Electrons” Radiation Protection Dosimetry. Vol. 149, 101-108 (03/2012)

 Myonggeun Yoon, “Development and current status of proton therapy for lung cancer in Korea” Thoracic Cancer. 3, 1-7 (02/2012)

 Hojin Jeong, Jeong-Eun Rah, Ui-Jung Hwang, Seung Hoon Yoo, Byung Jun Min, Sang-Yeob Lee, Myonggeun Yoon, Dong Ho Shin, Sung Yong Park, Se Byeong Lee and Joo-Young Kim, “Estimation of the secondary cancer risk induced by diagnostic imaging radiation during proton therapy” J. Radiol. Prot. 31, 477–487 (12/2011)

 Myonggeun Yoon, Dong Ho Shin, Jinsung Kim, Jong Won Kim, Dae Woong Kim, Sung Yong Park, Se Byeong Lee, Joo Young Kim, Hyeon-Jin Park, Byung_Kiu Park and Sang Hoon Shin, “Craniospinal Irradiation Techniques: A Dosimetric Comparison of Proton Beams with Standard and Advanced Photon Radiotherapy” Int. J. Radiat. Biol. Phys. Volume 81, Issue 3, 637-646 (09/2011)

 S.A. Park, J.W. Kwak, Myonggeun. Yoon, D.H. Shin, S.B. Lee, K.H. Cho, S.K. Kang, K.J. Kim, H.S. Bae, S.Y. Park, “Dose verification of proton beam therapy using the Gafchromic EBT film” Radiation Measurement 46, 717-721 (07/2011)

 Young Kyung Lim, Ui-Jung Hwang, Dongho Shin, Dong Wook Kim, Jungwon Kwak, MyonggeunYoon, Doo Hyun Lee, Se Byeong Lee, Sang-Yeob Lee, Sung Yong Park, Hong Ryeol Pyo “Proton range uncertainty due to bone cement injected into the vertebra in radiation therapy planning” Medical Dosimetry. Vol 36, 299-305 (07/2011)

 Dong Wook Kim, Young Kyung Lim, Sung Hwan Ahn, Jungwook Shin, Dongho Shin, Myongguen Yoon, Se Byeong Lee, Dae Yong Kim, Sung Yong Park “Prediction of output factor, range, and spread-out Bragg peak for proton therapy” Medical Dosimetry. Vol 36,145-152 (04/2011)

 Seonkyu Kim, Myonggeun Yoon, Dong Ho Shin, Dongwook Kim, Sangyeob Lee, Se Byeong Lee, Sung Yong Park, Sang Hyuk Song, “Feasibility of deformation-independent tumor-tracking radiotherapy during respiration” Journal of Medical Physics 36, 78-84 (04/2011)

 Myonggeun Yoon, Minho Cheong, Jinsung Kim, Dong Ho Shin, Sung Yong Park, Se Byeong Lee, “Accuracy of an automatic patient positioning system based on the correlation of two edge images in radiotherapy” Journal of Digital Imaging. Volume 24, Issue 2, 322-330 (04/2011)

 Seonkyu Kim, Byung Jun Min, Myonggeun Yoon, Jinsung Kim, Dong Ho Shin, Se Byeong Lee, Sung Yong Park, Sungkoo Cho, Dae Hyun Kim, “Secondary radiation doses of intensity-modulated radiotherapy and proton beam therapy in patients with lung and liver cancer” Radiotherapy and Oncology. Volume 98, 335-339 (03/2011)

 Jeong-Eun Rah, Ui-Jung Hwang, Hojin Jeong, Sang-Yeob Lee, Doo-Hyun Lee, Dong Ho Shin, Myonggeun Yoon, Se Byeong Lee, Rena Lee, Sung Yong Park, “Clinical application of glass dosimeter for in vivo dose measurements of total body irradiation treatment technique” Radiation Measurements. Volume 46, 40-45 (01/2011)

 Kwan Ho Cho, Jooyoung Kim, Seunghoon Lee, Heon Yoo, Sanghoon Shin, Sungho Moon, Taehyun Kim, Kyung hwan Shin, Myonggeun Yoon, Doo-hyun Lee and Hong Ryull Pyo, “Simultaneous Integrated Boost-Intensity Modulated Radiotherapy in Patients with High-Grade Gliomas” Int. J. Radiat. Biol. Phys. Volume 78, Issue2, 390-397 (10/2010)

Myonggeun Yoon, Sung Hwan Ahn, Jinsung Kim, Dong Ho Shin, Sung Yong Park, Se Byeong Lee, Kyung Hwan Shin, and Kwan Ho Cho, “Radiation-induced cancers from modern radiotherapy techniques: IMRT vs. Proton Therapy” Int. J. Radiat. Biol. Phys. Volume 77, Issue5, 1477-1485 (08/2010)

 Sungkoo Cho, Jong Hwi Jeong,Chan Hyeong Kim, Myonggeun Yoon, “Monte Carlo Simulation Study on Dose Enhancement by Gold Nanoparticles in Brachytherapy” Journal of the Korean Physical Society. Vol56, No.6, 1754-58 (06/2010)

 Dong Wook Kim Jungwook Shin, Sung Hwan Ahn, Sang Yeob Lee, Dongho Shin,_Myonggeun Yoon, Se Byeong Lee and Sung Yong ParkYoung Kyung Lim Rena Lee, “Measurement of the Secondary Neutron Dose Generated During Proton Beam Therapy for Craniospinal Irradiation” Journal of the Korean Physical Society. Vol56, No.3, 1208-1214 (04/2010)

 Soah Park, Kwang-Ho Cheong, Tai-Jin Hwang, Sei-Kwon Kang, Meyeon Lee, Kyoung-Joo Kim, Do Hoon Oh, Hoonsik Bae, Myonggeun Yoon, Taeyoon Kim, Dongwook Kim, Dongho Shin, Sung Yong Park_ and Kwan Ho Cho, “When Should an Adaptive Plan be Considered for Head-and-neck Cancer Patients Undergoing Tomotherapy Treatment?” Journal of the Korean Physical Society. Vol56, No.3, 897-904 (03/2010)

 Jungwook Shin, Dongwook Kim, Young Kyung Lim, Sunghwan Ahn, Dongho Shin, Myonggeun Yoon, Sung-Yong Park and Se Byeong Lee, Jungwon Kwak, Dongchul Son, “Monte Carlo Modeling and Simulation of a Passive Treatment Proton Beam Delivery System using a Modulation Wheel” Journal of the Korean Physical Society. Vol56, No.1, 153-163 (01/2010)

Patents

 안구 종양 치료에서의 안구 추적 방법 10-0955686 (2010)

 입자방사선 치료용 표적 표시자 10-1074552 (2011)

 방사선량 검증 방법 및 장치 10-1446872 (2014)

 광자극 발광 선량계 방사선량 측정용 팬텀 10-1473744 (2014)

 근접방사선 선량 측정용 팬텀 10-1445597 (2014)

 Method of tracking eyeball in eyeball tumor treatment US8638982 (2014)

저서

[Khan’s 방사선치료물리학] 바이오메디북, 공동(번역), 2013

연구분야

 Development of proton dosimetry system using an array of fiber-optic cerenkov radiation sensor

 Development of real-time radiation beam monitoring system

 Development of reconstruction algorithm for the verification of treatment doses

 Development of regulation technology for quality assurance in radiotherapy system

 Treatment of cancer cell using alternating electric fields

수상경력

Young Investigator Award (Korean Society of Medical Physicists, 2007)

Best Paper of the Year (Korean Society of Medical Physicists, 2006)